Hybrid header lightAlma Hybrid CO2 and 1570 nm laser platform

Alma Hybrid
The Future of Skin Rejuvenation



Hybrid headerAlma Hybrid CO2 and 1570 nm laser platform

Alma Hybrid Transform Your Patients Skin

Bringing together a unique combination of three powerful energies, Alma Hybrid sets a new standard in skin rejuvenation, resurfacing and scar treatment. With a dual laser strategy that delivers a fully customisable ratio of ablative and non-ablative wavelengths, Alma Hybrid offers limitless options and ultimate control that go far beyond standard fractional laser.

Comparing Alma Hybrid with Alma Pixel CO2? Read our guide to professional CO2 laser machines and systems, with a side-by-side table.

Hybrid headerAlma Hybrid CO2 and 1570 nm laser platform

Alma Hybrid
Master Your Craft



  • Treatments

    Skin Rejuvenation, Skin Resurfacing and Scar treatment

  • Downtime

    Flexible downtime

  • Skin Type

    I-VI

  • Available applicators

    2

Customised to Perfection

The HyGrid lasing mode enables complete customisation of the ablative (CO2 laser)/non-ablative (Erbium laser) ratio through a carefully planned matrix of micro-dots that addresses each patient’s unique treatment needs.

Alma Hybrid model
Alma Hybrid: Customised to Perfection

Best-Practice Presets

Based on extensive protocol development in cooperation with experienced doctors, as well as vast pre-clinical and clinical research, we have created a series of presets that address relevant indications and patient-specific requirements. Presets are selected through a highly intuitive user interface that enables simple operation from day one, while ensuring optimal results.

Alma Hybrid CO2 and 1570 nm laser platform
Alma Hybrid: Best-Practice Presets

Tools of a Master Craftsman

The highly advanced, automated ProScan scanner realises HyGrid’s full capabilities by providing an effect that is ablative, coagulative, and thermal all at once (or separately if needed). This lightweight, ergonomically designed applicator boasts a cooled tip to enhance treatment safety and patient comfort, and offers a range of different scanning shapes and modes to enable rapid coverage of large surface areas.
Discover how the Alma Hybrid can elevate your clinic
Book a demo now

Popular Treatments B&A

Alma Hybrid: Skin Resurfacing
Alma Hybrid: Skin Resurfacing

Skin Resurfacing

Courtesy of Jeffrey Hsu, MD, FAAD

Alma Hybrid Scars Dr Artzi forehead after
Alma Hybrid Scars Dr Artzi forehead b

Scars

Courtesy of Dr Ofir Artzi

Alma Hybrid: Skin Resurfacing
Alma Hybrid: Skin Resurfacing

Skin Resurfacing

Courtesy of Jeffrey Hsu, MD, FAAD

Alma Hybrid: skin resurfacing
Alma Hybrid: skin resurfacing

skin resurfacing

Courtesy of Dr Pina Panchal

Alma Hybrid_ Scars Dr Artzi nose after
Alma Hybrid_ Scars Dr Artzi nose before

Scars

Courtesy of Dr Ofir Artzi

After | Hybrid | Fine lines and Wrinkles
Before | Hybrid | Fine lines and Wrinkles

Fine Lines and Wrinkles

Courtesy of Dr Pina Panchal

Alma Hybrid: skin resurfacing
Alma Hybrid: skin resurfacing

skin resurfacing

Courtesy of Dr Pina Panchal

Alma Hybrid: skin resurfacing
Before and after treatment result, Alma Hybrid CO2 and 1570 nm laser platform; individual results vary

skin resurfacing

Courtesy of Dr Aristides Arellano

Scars | Hybrid | After
Scars \ Before \ Hybrid

Post Traumatic Scar

Courtesy of: Dr. Munir Somji

Skin Rejuvenation after | Hybrid
Skin Rejuvenation before | Hybrid

Skin Rejuvenation

Courtesy of Dr. Jeffrey Hsu

After | Skin Resurfacing | Hybrid
Before Hybrid | Skin Resurfacing

Skin Resurfacing

Courtesy of Dr. Aristides Arellano Huacuja

Courtesy of Dr Aristides Arellano Huacuja After
Courtesy of Dr Aristides Arellano Huacuja Before

Scars

Courtesy of Dr Aristides Arellano Huacuja

Alma Hybrid: Active Acnes
Alma Hybrid: Active Acnes

Active Acnes

Courtesy of Dr Kimberlee Smith

Award Winning Design

Alma Hybrid CO2 and 1570 nm laser platform
  • Alma Hybrid: Award Winning Design
Alma Hybrid CO2 and 1570 nm laser platform
Streamlined and ultra-modern in both design and capabilities, the stylish Alma Hybrid has won multiple awards.

Leading Technologies

  • co2 - Hybrid
    The optimal blend of ablative, coagulative and thermal effect for efficient, highly-precise focus or fractional laser treatments that offer the perfect resurfacing.
  • Alma Hybrid: Leading Technologies
    A powerful non-ablative laser that creates the ultimate deep thermal effect, promoting new dermis synthesis, while leaving the epidermis intact.
  • IMPACT - Hybrid
    Our patented IMPACT Ultrasound technology creates an acoustic pressure, designed to enhance trans-epidermal delivery through the micro-channels created by the CO2 laser for improves overall results.
  • Alma Hybrid: Leading Technologies
    A revolutionary application that supports Alma Hybrid’s dual laser strategy by enabling complete customisation of the ablative (CO2 laser)/non-ablative (Erbium laser) ratio.

Relevant Applicators

Alma Hybrid: what clinics ask before they buy

Alma Hybrid is Alma’s top-tier ablative laser platform and the only one that fires an ablative CO2 beam and a non-ablative 1570 nm beam side by side in the same pass, in a ratio the practitioner sets, or in sequence when the case calls for it. One console covers skin resurfacing and rejuvenation, acne and surgical and burn scars, keloid management, fine lines, striae, skin laxity and benign lesions, on skin types I to VI, with no consumables.

What qualifications or approval do you need to operate the Alma Hybrid?

Two separate things, and clinics often conflate them. Device approval: in Australia Alma Hybrid is included in the Australian Register of Therapeutic Goods under entry 321320, with Alma Lasers Australia Pty Ltd as sponsor, Class IIb. Operator requirements: these are set by each state and territory, not by Alma, and they differ. Queensland, Tasmania and Western Australia licence laser use; other states apply different rules, and requirements change. Our Laser and IPL Regulations page keeps the current position for every state, and we take each clinic through what applies to them before installation. Whatever the state rule, every installation includes on-site clinical training for your team by an Alma clinical specialist.

What is the clinical advantage of Alma Hybrid?

Control over the trade-off between result and downtime. HyGrid lets you set the ablative to non-ablative ratio inside a single matrix of micro-dots, so an aggressive resurfacing for deep acne scars and a low-downtime rejuvenation for a first-time patient run on the same machine with the same ProScan applicator. Pixel Peel mode fires the fractional beam in a randomised pattern rather than a fixed grid, so neighbouring columns cool before the next shot lands, which respects the tissue’s thermal relaxation time and lowers downtime again.

What is unique about it?

Three things. The two wavelengths fired together rather than in separate passes. The ProScan automated scanner with a cooled tip, which lases both wavelengths. And the IMPACT ultrasound applicator, which uses acoustic pressure to drive skin-approved topicals through the micro-channels the CO2 has just opened, so the treatment does not end when the laser stops.

What are the main indications?

Skin rejuvenation and resurfacing, acne scars, surgical scars, burn scars and keloid management, fine lines and wrinkles, striae, skin laxity, benign lesions and active acne. Published work on the platform includes Arellano-Huacuja on keloid management with a combined continuous-wave and repeat fractionated CO2 regimen, Tsur Shenhav and colleagues on the dual CO2 and 1570 nm laser for periorbital rejuvenation, and Somji and Solomon on the 1570 nm scanner for non-ablative face and neck rejuvenation.

Is it worth it compared with a CO2-only laser?

Alma Hybrid does everything Alma Pixel CO2 does and adds the 1570 nm wavelength and IMPACT. If your clinic is built on scar revision and rejuvenation where comfort and short downtime drive rebooking, that is the argument. If you want a proven fractional and surgical CO2 platform at a lower entry point, Pixel CO2 is the one. The side-by-side comparison is on our professional CO2 laser machines page.

What does it cost, and is finance available?

We do not publish list prices, because the platform is configured to the clinic. There are no consumables, so after purchase the cost per treatment is practitioner time. Every quote includes installation, clinical training and a 12-month factory warranty. Equipment finance is available through Australian lenders including Medfin. Request pricing and we will come back with a configured quote for your clinic in Australia or New Zealand.

This is What the Experts Are Saying About Alma Hybrid

Clinical evidence and running costs

Clinical evidence. Three peer-reviewed studies on the dual CO2 and 1570 nm Hybrid approach are listed on our clinical evidence page, with journal, year and first author for each paper. The full searchable library is in Clinical Resources.

Running costs. Alma Hybrid has no per-treatment consumables: no single-use tips, cartridges, pulse cards or proprietary gels. Ongoing cost is applicator life, servicing and ordinary clinic supplies. How running costs compare across aesthetic devices.

Genuine Alma. Systems supplied by Alma Lasers Australia are included in the ARTG, carry an Alma serial number registered with Alma, and come with manufacturer warranty and local clinical training. How to tell a genuine Alma device from a lookalike. More questions from clinic owners are answered in our Q&A for clinics.

Alma Hybrid CO2 and 1570 nm laser platform

Clinical Resources

  • Use of a fractional 1570-nm diode laser scanner for non-ablative face and neck rejuvenation

    Munir Somji 1, Tino Solomon 1
    2024 The Authors. Journal of Cosmetic Dermatology published by Wiley Periodicals LLC.

    Read More
  • Effective keloid management using a combinatorial continuous-wave and repeat fractionated ablative CO2 laser regimen

    Aristides Arellano-Huacuja 1
    2024 The Authors. Journal of Cosmetic Dermatology published by Wiley Periodicals LLC.

    Read More
  • The Safety and Efficacy of a Dual CO2 and 1570-nm Hybrid Laser for Periorbital Rejuvenation.

    Leah Tsur Shenhav, Waseem Shehade, Gerardo Muravnik, Tamir Horovitz, Ofir Artzi
    Dermatol Surg. 2023 May

    Read More

FAQs

  • Describe outcomes as ranges over a course, not a single-session transformation. Laser hair removal reduces hair over several sessions because hair grows in cycles; skin treatments improve tone and texture gradually; body contouring shows change over weeks as the body responds. Photographs should be the clinic’s own, with the treatment and interval stated, and patients should be told that results vary and that suitability is assessed at consultation.

    This honest framing is also what Australian advertising rules for regulated health services expect. Alma Lasers Australia provides consultation guidance with its clinical training.

  • Alma platforms are supported by peer-reviewed clinical studies and by the ARTG inclusion of the devices supplied by Alma Lasers Australia. Clinics can read the published studies by platform or browse the clinical resources library on this website, request study summaries from their Alma representative, and attend Alma Academy sessions where Australian practitioners present protocols and case series for local skin types.

    Alma Lasers Australia is building an Australian case library with clinics that agree to share anonymised before-and-after series. Clinics interested in contributing can contact their representative.

  • They answer different questions. Alma Opus uses fractional plasma to resurface and tighten with a short recovery, and it is often chosen by clinics whose patients want texture, fine lines and laxity treated with a few days of downtime. Alma Hybrid combines an ablative CO2 laser with a 1570 nm non-ablative laser, so the practitioner can dial from a light treatment up to deep resurfacing for scars and significant sun damage on the same platform.

    Clinics with a strong scar and resurfacing menu usually choose Hybrid; clinics adding resurfacing to a broader aesthetic menu often start with Opus. Note that Opus uses treatment tips as a consumable while Hybrid does not. Alma Lasers Australia can arrange a demonstration of both.

  • Every installation includes on-site clinical training by Alma’s Australian clinical team, protocol guides for each applicator, and follow-up training when a clinic adds staff or applicators. Ongoing education runs through Alma Academy: in-house workshops, advanced masterclasses and hands-on sessions in Sydney, Melbourne and Brisbane.

    Service engineers, applicator support and loan arrangements are handled from Australia, and each clinic has a named Alma representative. Clinics can request refresher training at any time.

  • It depends on the platform and how it is set. Non-ablative treatments such as Harmony XL Pro ClearLift typically have no visible downtime beyond mild redness. Alma Opus fractional plasma usually involves a few days of redness and light peeling. Alma Hybrid ranges from a short recovery when the 1570 nm laser dominates to several days of redness, swelling and crusting when the CO2 component is set deeper.

    Clinics should quote a range, not a single day count, and explain that a deeper single session and a lighter course are both valid ways to reach a result. Alma Lasers Australia’s training covers how to set expectations for each protocol.

More Questions
Loading...